855-919-5257
End yoke not torqued to correct specification Not using correct torque tool
Contamination caused by lack of proper cleaning of axle housing including removal of wheel ends.
Incomplete process of replacing the differential due to not:
Failure to use approved lubricants. Failure to top off lubricants. Failure to road test and recheck Mixed fluids in system
Failure to inspect driveline and suspension components for systems deficiencies.
Component failures due to vibration – vibration caused by faulty driveline/suspension